N3K-C3164Q-40GE Specification
|
Physical
|
· 2 RU fixed form-factor switch
· 64 QSFP+ ports; each supports native 40 Gigabit Ethernet and 4 x 10 Gigabit Ethernet modes
· 2 redundant power supplies
· 3+1 redundant fans
· Management, console, and USB flash-memory ports
|
Performance
|
· 5.12 Tbps switching capacity
· Forwarding rate up to 3.8 bpps
· Line-rate traffic throughput (both Layer 2 and 3) on all ports
· Configurable maximum transmission units (MTUs) of up to 9216 bytes (jumbo frames)
|
Hardware tables and scalability
|
Number of VLANS
|
MSTP: 4096
|
Number of spanning-tree instances
|
MSTP: 64
RPVST+: 507
|
Number of access control list (ACL) entries
|
4000 to 16000 ingress
1000 to 4000 egress
|
Routing table
|
Maximum number of longest prefix match (LPM) routes 128,000
Maximum number of IP host entries 120,000
Maximum number of MAC address entries 96,000
|
Number of EtherChannels
|
256
|
Number of ports per EtherChannel
|
32
|
Buffer size
|
48 MB shared
|
System memory
|
16 GB
|
Power
|
Frequency
|
50 to 60 Hz
|
Power supply types
|
AC
|
Typical operating power
|
803 Watts (W) with SR4 optics at 100% load; 2 PSUs
|
Maximum power
|
1100 Watts (W)
|
AC PSUs
· Input voltage
· Frequency
· Efficiency
|
· 200 to 240 VAC
· 50 to 60 Hz
· 93% at 220V
|
Typical heat dissipation
|
2739 BTU/hr (with SR4 optics at 100% load)
|
Maximum heat dissipation
|
3753 BTU/hr
|
Cooling
|
Port-side intake and port-side exhaust options
Port-side intake: Yes
Port-side exhaust: Post FCS
|
Dimensions
|
· Dimensions (height x width x depth)
|
3.48 x 17.41 x 22.32in. (88.4 x 442 x 566 mm)
|
Environment
|
Weight
|
37 lb (16.8kg)
|
Operating temperature
|
32 to 104°F (0 to 40°C)
|
Storage temperature
|
-40 to 158°F (-40 to 70°C)
|
Operating relative humidity
|
· 10 to 85% noncondensing
· Up to 5 days at maximum (85%) humidity
Recommend ASHRAE data center environment
|
Storage relative humidity
|
5% to 95% noncondensing
|
Altitude
|
0 to 10,000 ft (0 to 3000m)
|